Event Source 2 - WMIxWDM
Processor Number : 0
Bank Number : 0
Time Stamp (0x): 01C8C4CC 43A7F4F8
Error Status (0x): C427C000 00000833
Error Address (0x): 00000000 43DE8CC0
Error Misc. (0x): 00000000 00000000
Status Bit Decode:
Correctable ECC error
Error address valid in MCi_ADDR
Second error
Error valid
Bus Error Code:
Participation processor: Local node originated the request (SRC)
Time-out: Request did not time out
Memory transaction type: Data read (DRD)
I/O: DRAM memory access (MEM)
Cache level: Generic (LG)
Data Cache Error MC0:
System line fill error into data cache
Syndrome: 0x4F
---
Event Source 3 - WMIxWDM
Processor Number : 0
Bank Number : 2
Time Stamp (0x): 01C8C4CC 43A7F4F8
Error Status (0x): D0004000 00000863
Error Address (0x): 00000000 00000000
Error Misc. (0x): 00000000 00000000
Status Bit Decode:
Correctable ECC error
Error reporting enabled
Second error
Error valid
Bus Error Code:
Participation processor: Local node originated the request (SRC)
Time-out: Request did not time out
Memory transaction type: Prefetch
I/O: DRAM memory access (MEM)
Cache level: Generic (LG)
Bus Unit Error MC2:
System Data ECC error on Hardware Prefetch access
---
Event Source 4 - WMIxWDM
Processor Number : 0
Bank Number : 4
Time Stamp (0x): 01C8C4CC 43A7F4F8
Error Status (0x): D42DC001 00000813
Error Address (0x): 00000000 43DE83F8
Error Misc. (0x): 00000000 00000000
Status Bit Decode:
Error associated with CPU0 core
Correctable ECC error
Error address valid in MCi_ADDR
Error reporting enabled
Second error
Error valid
Bus Error Code:
Participation processor: Local node originated the request (SRC)
Time-out: Request did not time out
Memory transaction type: Generic read (RD)
I/O: DRAM memory access (MEM)
Cache level: Generic (LG)
North Bridge Error MC4:
Extended Error Code: 0x0 - ECC Error
Error Code: 0x0813
DRAM memory access (MEM) Generic read (RD), on Generic (LG) cache on CPU0
Correctable Single-bit ECC Error
ECC Syndrome: 0x5B
Error on bit: 38
Error address at 1085 MB
Address decode:
Node ID0, Chip Select3, Logical DIMM1
---
Event Source 6 - WMIxWDM
Processor Number : 0
Bank Number : 4
Time Stamp (0x): 01C8C6D8 422A05E8
Error Status (0x): 94254001 00000813
Error Address (0x): 00000000 43DE8CB8
Error Misc. (0x): 00000000 00000000
Status Bit Decode:
Error associated with CPU0 core
Correctable ECC error
Error address valid in MCi_ADDR
Error reporting enabled
Error valid
Bus Error Code:
Participation processor: Local node originated the request (SRC)
Time-out: Request did not time out
Memory transaction type: Generic read (RD)
I/O: DRAM memory access (MEM)
Cache level: Generic (LG)
North Bridge Error MC4:
Extended Error Code: 0x0 - ECC Error
Error Code: 0x0813
DRAM memory access (MEM) Generic read (RD), on Generic (LG) cache on CPU0
Correctable Single-bit ECC Error
ECC Syndrome: 0x4A
Error on bit: 33
Error address at 1085 MB
Address decode:
Node ID0, Chip Select3, Logical DIMM1
---
Event Source 14 - WMIxWDM
Processor Number : 1
Bank Number : 2
Time Stamp (0x): 01C8C6DD B4E9AFE8
Error Status (0x): 90004000 00000863
Error Address (0x): 00000000 00000000
Error Misc. (0x): 00000000 00000000
Status Bit Decode:
Correctable ECC error
Error reporting enabled
Error valid
Bus Error Code:
Participation processor: Local node originated the request (SRC)
Time-out: Request did not time out
Memory transaction type: Prefetch
I/O: DRAM memory access (MEM)
Cache level: Generic (LG)
Bus Unit Error MC2:
System Data ECC error on Hardware Prefetch access
---
Event Source 21 - WMIxWDM
Processor Number : 0
Bank Number : 4
Time Stamp (0x): 01C8CD8C 279EFFCA
Error Status (0x): D42EC000 00000A13
Error Address (0x): 00000000 43DE9A78
Error Misc. (0x): 00000000 00000000
Status Bit Decode:
Correctable ECC error
Error address valid in MCi_ADDR
Error reporting enabled
Second error
Error valid
Bus Error Code:
Participation processor: Local node responded to the request (RES)
Time-out: Request did not time out
Memory transaction type: Generic read (RD)
I/O: DRAM memory access (MEM)
Cache level: Generic (LG)
North Bridge Error MC4:
Extended Error Code: 0x0 - ECC Error
Error Code: 0x0A13
DRAM memory access (MEM) Generic read (RD), on Generic (LG) cache
Correctable Single-bit ECC Error
ECC Syndrome: 0x5D
Error on bit: 39
Error address at 1085 MB
Address decode:
Node ID0, Chip Select3, Logical DIMM1
---
Event Source 24 - WMIxWDM
Processor Number : 0
Bank Number : 4
Time Stamp (0x): 01C8CE55 2E4579CA
Error Status (0x): 942EC000 00000A13
Error Address (0x): 00000000 43DE9A78
Error Misc. (0x): 00000000 00000000
Status Bit Decode:
Correctable ECC error
Error address valid in MCi_ADDR
Error reporting enabled
Error valid
Bus Error Code:
Participation processor: Local node responded to the request (RES)
Time-out: Request did not time out
Memory transaction type: Generic read (RD)
I/O: DRAM memory access (MEM)
Cache level: Generic (LG)
North Bridge Error MC4:
Extended Error Code: 0x0 - ECC Error
Error Code: 0x0A13
DRAM memory access (MEM) Generic read (RD), on Generic (LG) cache
Correctable Single-bit ECC Error
ECC Syndrome: 0x5D
Error on bit: 39
Error address at 1085 MB
Address decode:
Node ID0, Chip Select3, Logical DIMM1
---
Event Source 30 - WMIxWDM
Processor Number : 1
Bank Number : 0
Time Stamp (0x): 01C8DBE5 90077C24
Error Status (0x): 842EC000 00000833
Error Address (0x): 00000000 43DE9A40
Error Misc. (0x): 00000000 00000000
Status Bit Decode:
Correctable ECC error
Error address valid in MCi_ADDR
Error valid
Bus Error Code:
Participation processor: Local node originated the request (SRC)
Time-out: Request did not time out
Memory transaction type: Data read (DRD)
I/O: DRAM memory access (MEM)
Cache level: Generic (LG)
Data Cache Error MC0:
System line fill error into data cache
Syndrome: 0x5D
---
Event Source 71 - WMIxWDM
Processor Number : 0
Bank Number : 2
Time Stamp (0x): 01C941DA C25E4EEA
Error Status (0x): D0004000 00000863
Error Address (0x): 00000000 00000000
Error Misc. (0x): 00000000 00000000
Status Bit Decode:
Correctable ECC error
Error reporting enabled
Second error
Error valid
Bus Error Code:
Participation processor: Local node originated the request (SRC)
Time-out: Request did not time out
Memory transaction type: Prefetch
I/O: DRAM memory access (MEM)
Cache level: Generic (LG)
Bus Unit Error MC2:
System Data ECC error on Hardware Prefetch access